A
AKHAND BHARAT
Group
Ultra-High Precision CV / EIS Battery Testing System
Featured

Ultra-High Precision CV / EIS Battery Testing System

SKU: ABG-BTTV-CELL-CVEIS

High-precision battery cell testing platform for cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and controlled charge–discharge characterization for advanced battery research and validation.

Overview

A high-precision electrochemical testing platform for battery materials and cell research, combining controlled battery testing with Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) on applicable configurations.

Key Features & Highlights

Integrated CV / EIS workflow

Selected configurations combine electrochemical characterization with charge/discharge testing without moving the battery between systems.

24-bit acquisition

The referenced CT-8002S-5V100mA-EIS model uses 24-bit AD and 16-bit DA resolution.

High precision

The referenced CT-8002S-5V100mA-EIS model specifies ±0.01% F.S. voltage and current accuracy.

Six current ranges

The referenced model provides six current ranges from 0.1 mA through 100 mA.

Key Capabilities

Cyclic Voltammetry

Controlled voltage scanning for electrochemical reaction and redox characterization.

Electrochemical Impedance Spectroscopy

Impedance characterization for electrochemical interfaces and battery behavior.

Charge / discharge

Battery performance testing can be integrated into the research workflow.

Multi-dimensional characterization

Supports workflows combining CV/EIS with cycling and other electrochemical methods where configured.

Applications

Battery materials research

Electrode, electrolyte and interface characterization.

Solid-state battery research

Electrochemical interface and impedance studies.

Sodium-ion research

Electrochemical behavior and interfacial analysis.

Cell development

Advanced characterization during prototype development.

Industries Served

Battery R&D laboratories

Advanced electrochemical research and cell development.

Universities

Materials and electrochemistry research.

Battery manufacturers

Root-cause and performance characterization.

Research institutes

Next-generation battery technology development.

Testing / Operating Workflow

1

1. Prepare test cell

Install the cell using the appropriate fixture and electrical configuration.

2

2. Select electrochemical method

Configure CV, EIS, cycling or a combined sequence.

3

3. Execute measurement

Acquire high-resolution voltage/current response and impedance data.

4

4. Correlate results

Relate electrochemical signatures to cell performance and degradation.

Software & Data Management

Programmable test sequences

Combine electrochemical and charge/discharge steps within the supported BTS workflow.

Data analysis

Record and analyze test results for research and validation reporting.

Safety & Protection

Electrical protection

Operate within the voltage, current and power limits of the selected model and DUT.

Four-wire measurement

Applicable configurations can use precision measurement techniques to reduce lead-resistance effects.

System Integration

Research fixtures

Coin-cell and other laboratory fixtures can be selected for the DUT.

Environmental testing

Temperature-control equipment can be integrated where the research protocol requires it.

Configuration Options

Referenced model

CT-8002S-5V100mA-EIS.

Voltage

Referenced model output range: -5 V to +5 V; minimum discharge voltage -5 V.

Current

Referenced model ranges: 0.1 mA, 1 mA, 5 mA, 10 mA, 50 mA and 100 mA.

Benefits & Value Proposition

Higher-resolution electrochemical insight

Supports detailed analysis beyond conventional capacity/cycle measurements.

Integrated research workflow

Reduces the need to move the DUT between separate battery cycling and electrochemical measurement platforms.

Frequently Asked Questions

Which model is the technical reference for this page?

The detailed numerical specification on this page is based on CT-8002S-5V100mA-EIS. Other configurations are available according to the application.

Does the system support both CV and EIS?

Yes, where the selected configuration includes the corresponding CV/EIS functions.

Technical Specifications

Reference modelABG CT-8002S-5V100mA-EIS
ResolutionAD 24-bit; DA 16-bit
Voltage output-5 V to +5 V
Voltage accuracy±0.01% F.S.
Current ranges0.1 mA / 1 mA / 5 mA / 10 mA / 50 mA / 100 mA
Current accuracy±0.01% F.S.
Single-channel output power0.5 W
FunctionsCV / EIS / battery charge-discharge testing

Technical buying guidance

Related buyer guides & requirements

Tell Us About Your Testing Requirement

Share what you already know. You do not need to have every specification finalized before starting a technical discussion.